IntermediateTopic 50 of 101Signals, Control & Comms

Steady-state error

Final error depends on system type and input; integrators remove it.

In depth

For unity feedback, final error depends on system type (number of integrators) and input: type 0: step error 1/(1+K_p); type 1: zero for step, 1/K_v for ramp; type 2: zero for ramp. Final value theorem e_ss=lim sE(s). Integral action eliminates constant error.

Key points

  • Position, velocity, acceleration constants
  • Disturbance steady-state error
  • Type number
Example

A type-1 positioning system follows a step reference with zero steady-state error.

Why it matters

Steady-state error shows whether a control system reaches the target accurately, which matters for setpoint tracking and disturbance rejection.

Where this is used

  • Checking that a motor speed controller holds its target under load.
  • Choosing an integrator in a loop to remove offset in a temperature control.
  • Specifying the tracking error for a ramp input to a machine axis.

Frequently asked questions

What is Steady-state error?

Final error depends on system type and input; integrators remove it.

Why is it important to understand steady-state error?

Steady-state error shows whether a control system reaches the target accurately, which matters for setpoint tracking and disturbance rejection.

Why does an integrator remove steady-state error?

It accumulates the error over time, so a constant error keeps increasing the control action until the error is zero.

What depends on the system type?

The number of pure integrators in the open-loop transfer function sets the steady-state error for step, ramp and parabolic inputs.

How is Steady-state error used in practice?

Typical applications include checking that a motor speed controller holds its target under load, choosing an integrator in a loop to remove offset in a temperature control and specifying the tracking error for a ramp input to a machine axis.

What should I learn before Steady-state error?

Study "Time-domain specifications" first (topic 49 of 101 in Signals, Control & Comms). It covers the groundwork this topic builds on.

What are the key points of Steady-state error?

Position, velocity, acceleration constants. Disturbance steady-state error. Type number.

Can you give an example of Steady-state error?

A type-1 positioning system follows a step reference with zero steady-state error.

What comes after Steady-state error?

The next topic is "Stability and Routh-Hurwitz", which builds directly on this one.

How difficult is Steady-state error?

It is classed as Intermediate in Signals, Control & Comms (topic 50 of 101). It is an intermediate topic. Work through the beginner topics in Signals, Control & Comms first.